RowCool 70kW / 300W

RowCool 70kW / 95kW

The most reliable and efficient cooling solutions
In order to offer the best possible space utilization, and to accommodate the potentially rapid expansion of new IT equipment, modern data centers have implemented a high-density model, based primarily on blade server technology. This model requires a higher power supply density, and can thereby create more significant problems with heat dissipation. In order to address these issues, round-the-clock air conditioning is sometimes deployed as a cooling system solution. However, the expense of using this method for data center cooling can end up accounting for up to 45% of the total electricity expenses incurred by the data center. With this in mind, heat dissipation and electricity expenses are important indices against which operational expenditures of the data center can be measured.
As a leading global manufacturer of fans and a specialist in power management, Delta Electronics was perfectly positioned to develop Delta InfraSuite Precision Cooling solutions in order to provide practical, optimized, innovative methods for data center cooling. Delta’s precision cooling enthalpy laboratory carefully verifies cooling system performance and reliability during the engineering development and design process to ensure high product performance.

Specialized forms of air conditioning and temperature control have been developed to cater to the unique cooling system needs of contemporary data centers. Traditional precision air conditioning is not appropriate in many cases as a data center cooling system. This type of air conditioning cannot provide adequate heat removal for data centers due to the problems of uneven heat distribution, load variations experienced during peak and off-peak periods, and high power density. An optimal data center cooling system must accommodate for each of these factors. Instead of traditional precision air conditioning methods, Delta InfraSuite Precision Cooling solutions employ either chilled water or refrigerant types to remove the heat produced by the hardware within the data center.

Cooling units can be installed in a modular rack design, which enables quick configuration and is readily expandable by load. Data center cooling by water is safe for the equipment it protects due in part to built-in leakage detectors, which can display leaks and offer alerts in a timely manner. With manual dehumidification capacity, Delta’s data center cooling system offers a rapid and precise means of adjusting the level of moisture within the air, and keeping humidity levels within the ideal range required by the data center equipment.

RowCool for effective heat removal in data centers

As the power density increases in modern data centers, traditional precision cooling fails to provide complete cooling for the following situations:
Load variations for peak and off-peak period
High power density
Uneven heat distribution
The Delta InfraSuite Precision Cooling RowCool Chilled Water can effectively solve the above problems.

Applications:

High power density rack area
Environment that requires precise environmental control

Watch the video

Features & Benefits

High Availability

  • Built-in dual input for better power reliability
  • Panel made of cold-rolled steel plate and coated with surface electrostatic spraying of epoxy is highly resistant to rust
  • Built-in leakage detector capable of leak display and alert
  • Modular rack design readily expandable by load to enable quick configuration of new cooling units
  • Built-in manual dehumidifying for quick and precise dehumidification
  • Supporting group control and used as backup

High Flexibility

  • Chilled water pipe suitable for both top and bottom insertion, with top and bottom input power wiring, providing flexible configuration as required
  • Wheels on bottom for easy moving to locations that need cooling
  • Disposable filter with high efficiency (MERV 8 ASHRAE 52.2)
  • Remote monitoring can be carried out through SNMP card, providing more comprehensive system protection
  • Optional reheater and humidifier accessories for more precise temperature and humidity control

High Efficiency

  • To comply with the high power density of racks, the RowCool series cooling capacity can increase up to 120kW (HCH1CD0) without changing footprint
    - for RowCool 95kW
  • When Applied to the high temperature settings of inlet water, outdoor units save on power consumption by up to 15~20% when the chiller water temperature increases from 5°C to 12°C
  • Continuously variable speed fan design for energy saving
  • Cooling system capable of variable flow control for energy saving
  • Built-in vortex wafer flow meter capable of monitoring chilled water flow that renders easy display of system status
Specifications
Downloads

Contact Us